Vulnerabilities (CVE)

Filtered by CWE-119
Total 14289 CVE
CVE Vendors Products Updated CVSS v2 CVSS v3
CVE-2025-7529 1 Tenda 2 Fh1202, Fh1202 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda FH1202 1.2.0.14(408). Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7528 1 Tenda 2 Fh1202, Fh1202 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda FH1202 1.2.0.14(408). Affected is the function fromGstDhcpSetSer of the file /goform/GstDhcpSetSer. The manipulation of the argument dips leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7527 1 Tenda 2 Fh1202, Fh1202 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda FH1202 1.2.0.14(408). It has been rated as critical. This issue affects the function fromAdvSetWan of the file /goform/AdvSetWan. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7506 1 Tenda 2 Fh451, Fh451 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda FH451 1.0.0.9. Affected by this vulnerability is the function fromNatlimit of the file /goform/Natlimit of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7505 1 Tenda 2 Fh451, Fh451 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function frmL7ProtForm of the file /goform/L7Prot of the component HTTP POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7468 1 Tenda 2 Fh1201, Fh1201 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda FH1201 1.2.0.14 and classified as critical. This vulnerability affects the function fromSafeUrlFilter of the file /goform/fromSafeUrlFilter of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7465 1 Tenda 2 Fh1201, Fh1201 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda FH1201 1.2.0.14. Affected by this vulnerability is the function fromRouteStatic of the file /goform/fromRouteStatic of the component HTTP POST Request Handler. The manipulation of the argument page leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7464 2026-06-17 2.6 LOW 3.7 LOW
A vulnerability classified as problematic has been found in osrg GoBGP up to 3.37.0. Affected is the function SplitRTR of the file pkg/packet/rtr/rtr.go. The manipulation leads to out-of-bounds read. It is possible to launch the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The name of the patch is e748f43496d74946d14fed85c776452e47b99d64. It is recommended to apply a patch to fix this issue.
CVE-2025-7463 1 Tenda 2 Fh1201, Fh1201 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda FH1201 1.2.0.14. It has been declared as critical. This vulnerability affects the function formWrlsafeset of the file /goform/AdvSetWrlsafeset of the component HTTP POST Request Handler. The manipulation of the argument mit_ssid leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7460 1 Totolink 2 T6, T6 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in TOTOLINK T6 4.1.5cu.748_B20211015 and classified as critical. Affected by this vulnerability is the function setWiFiAclRules of the file /cgi-bin/cstecgi.cgi of the component HTTP POST Request Handler. The manipulation of the argument mac leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7434 1 Tenda 2 Fh451, Fh451 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda FH451 up to 1.0.0.9 and classified as critical. Affected by this issue is the function fromAddressNat of the file /goform/addressNat of the component POST Request Handler. The manipulation of the argument page leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7423 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical was found in Tenda O3V2 1.0.0.12(3880). Affected by this vulnerability is the function formWifiMacFilterSet of the file /goform/setWrlFilterList of the component httpd. The manipulation of the argument macList leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7422 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability classified as critical has been found in Tenda O3V2 1.0.0.12(3880). Affected is the function setAutoReboot of the file /goform/setNetworkService of the component httpd. The manipulation of the argument week leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7421 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been rated as critical. This issue affects the function fromMacFilterModify of the file /goform/operateMacFilter of the component httpd. The manipulation of the argument mac leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7420 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been declared as critical. This vulnerability affects the function formWifiBasicSet of the file /goform/setWrlBasicInfo of the component httpd. The manipulation of the argument extChannel leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7419 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda O3V2 1.0.0.12(3880). It has been classified as critical. This affects the function fromSpeedTestSet of the file /goform/setRateTest of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7418 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability was found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this issue is the function fromPingResultGet of the file /goform/setPing of the component httpd. The manipulation of the argument destIP leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7417 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability has been found in Tenda O3V2 1.0.0.12(3880) and classified as critical. Affected by this vulnerability is the function fromNetToolGet of the file /goform/setPingInfo of the component httpd. The manipulation of the argument ip leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7416 1 Tenda 2 O3, O3 Firmware 2026-06-17 9.0 HIGH 8.8 HIGH
A vulnerability, which was classified as critical, was found in Tenda O3V2 1.0.0.12(3880). Affected is the function fromSysToolTime of the file /goform/setSysTimeInfo of the component httpd. The manipulation of the argument Time leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-7325 2 Cadsofttools, Irfanview 2 Cadimage, Irfanview 2026-06-17 N/A 7.8 HIGH
IrfanView CADImage Plugin DXF File Parsing Memory Corruption Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of IrfanView CADImage Plugin. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of user-supplied data, which can result in a memory corruption condition. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-26434.