CVE-2026-89034

TCH QRing smart ring model R20_B006 running firmware RT09R20_1.00.00_250318 contains an unauthenticated Bluetooth Low Energy access vulnerability that allows any nearby attacker to connect to the device without pairing, authentication, or user approval by exploiting the exposed Nordic UART Service which enforces no client authentication or command authorization. Attackers within Bluetooth Low Energy range can connect directly to the ring, bypassing the official application and cloud authentication, to read battery levels, activate live heart rate monitoring, and retrieve stored historical heart rate and blood oxygen records.
Configurations

No configuration.

History

16 Sep 2026, 22:18

Type Values Removed Values Added
New CVE

Information

Published : 2026-09-16 22:18

Updated : 2026-09-22 20:43


NVD link : CVE-2026-89034

Mitre link : CVE-2026-89034

CVE.ORG link : CVE-2026-89034


JSON object : View

Products Affected

No product.

CWE
CWE-306

Missing Authentication for Critical Function