CVE-2026-87674

A local privilege escalation vulnerability exists in the system logging daemon of Brocade Fabric OS versions before 9.2.2d and 10.0.0 through 10.0.0a1. Insufficient access controls on internal inter-process communication (IPC) channels allow an unprivileged local user to submit malformed logging configurations. Due to improper input sanitization during configuration file generation, an attacker can inject arbitrary directives that execute with elevated privileges when the logging service reloads, leading to local privilege escalation.
Configurations

Configuration 1 (hide)

OR cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*
cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*

History

14 Oct 2026, 19:11

Type Values Removed Values Added
First Time Broadcom fabric Operating System
Broadcom
CPE cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*
References () https://support.broadcom.com/external/content/SecurityAdvisories/0/39145 - () https://support.broadcom.com/external/content/SecurityAdvisories/0/39145 - Vendor Advisory
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 7.8

08 Oct 2026, 04:17

Type Values Removed Values Added
New CVE

Information

Published : 2026-10-08 04:17

Updated : 2026-10-14 19:11


NVD link : CVE-2026-87674

Mitre link : CVE-2026-87674

CVE.ORG link : CVE-2026-87674


JSON object : View

Products Affected

broadcom

  • fabric_operating_system
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')