CVE-2026-87670

An authorization logic vulnerability exists in the Brocade Fabric OS versions before 10.0.1 REST API gateway. The internal gate guarding restricted management endpoints relies exclusively on client-controlled HTTP headers. An authenticated user with any valid REST session can spoof these headers to gain unauthorized access to internal management endpoints. This allows low-privilege users to view sensitive chassis metadata, hardware memory patrolling state, and firmware integrity audit logs.
Configurations

Configuration 1 (hide)

cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*

History

13 Oct 2026, 17:16

Type Values Removed Values Added
References () https://support.broadcom.com/external/content/SecurityAdvisories/0/39140 - () https://support.broadcom.com/external/content/SecurityAdvisories/0/39140 - Vendor Advisory
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 4.3
CPE cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*
First Time Broadcom fabric Operating System
Broadcom

08 Oct 2026, 03:16

Type Values Removed Values Added
New CVE

Information

Published : 2026-10-08 03:16

Updated : 2026-10-13 17:16


NVD link : CVE-2026-87670

Mitre link : CVE-2026-87670

CVE.ORG link : CVE-2026-87670


JSON object : View

Products Affected

broadcom

  • fabric_operating_system
CWE
CWE-290

Authentication Bypass by Spoofing