A stack-based buffer overflow vulnerability exists in the diagnostic execution utility of Brocade Fabric OS versions before 10.0.1. When processing command arguments for diagnostic operations, the utility tokenizes user-supplied input into an internal argument array without enforcing boundary checks on the maximum array capacity. An authenticated user with administrative access can exploit this vulnerability by supplying a crafted diagnostic command string containing an excessive number of tokenized arguments. This leads to a memory overwrite resulting in a denial of service (process crash).
References
| Link | Resource |
|---|---|
| https://support.broadcom.com/external/content/SecurityAdvisories/0/39152 | Vendor Advisory |
Configurations
History
13 Oct 2026, 17:23
| Type | Values Removed | Values Added |
|---|---|---|
| CVSS |
v2 : v3 : |
v2 : unknown
v3 : 6.5 |
| CPE | cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:* | |
| References | () https://support.broadcom.com/external/content/SecurityAdvisories/0/39152 - Vendor Advisory | |
| First Time |
Broadcom fabric Operating System
Broadcom |
08 Oct 2026, 03:16
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-10-08 03:16
Updated : 2026-10-13 17:23
NVD link : CVE-2026-87668
Mitre link : CVE-2026-87668
CVE.ORG link : CVE-2026-87668
JSON object : View
Products Affected
broadcom
- fabric_operating_system
CWE
CWE-121
Stack-based Buffer Overflow