CVE-2026-87668

A stack-based buffer overflow vulnerability exists in the diagnostic execution utility of Brocade Fabric OS versions before 10.0.1. When processing command arguments for diagnostic operations, the utility tokenizes user-supplied input into an internal argument array without enforcing boundary checks on the maximum array capacity. An authenticated user with administrative access can exploit this vulnerability by supplying a crafted diagnostic command string containing an excessive number of tokenized arguments. This leads to a memory overwrite resulting in a denial of service (process crash).
Configurations

Configuration 1 (hide)

cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*

History

13 Oct 2026, 17:23

Type Values Removed Values Added
CVSS v2 : unknown
v3 : unknown
v2 : unknown
v3 : 6.5
CPE cpe:2.3:o:broadcom:fabric_operating_system:*:*:*:*:*:*:*:*
References () https://support.broadcom.com/external/content/SecurityAdvisories/0/39152 - () https://support.broadcom.com/external/content/SecurityAdvisories/0/39152 - Vendor Advisory
First Time Broadcom fabric Operating System
Broadcom

08 Oct 2026, 03:16

Type Values Removed Values Added
New CVE

Information

Published : 2026-10-08 03:16

Updated : 2026-10-13 17:23


NVD link : CVE-2026-87668

Mitre link : CVE-2026-87668

CVE.ORG link : CVE-2026-87668


JSON object : View

Products Affected

broadcom

  • fabric_operating_system
CWE
CWE-121

Stack-based Buffer Overflow