A flaw was found in the automation-controller API. The
unauthenticated health-check endpoint /api/v2/ping/
(ApiV2PingView, AllowAny) over-serializes RBAC-gated
automation-mesh data into its anonymous response, exposing the
full instance inventory (node hostnames, node types, UUIDs,
heartbeats, capacities, and exact versions), all instance-group
names and membership, the deployment install UUID, and the
active control node. A remote, unauthenticated attacker can use
this to map the control plane and fingerprint software versions
for targeted attacks. This flaw affects confidentiality only;
it does not expose secrets, credentials, or tenant data.
References
Configurations
No configuration.
History
24 Sep 2026, 07:16
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
24 Sep 2026, 04:18
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
23 Sep 2026, 23:18
| Type | Values Removed | Values Added |
|---|---|---|
| References |
|
23 Sep 2026, 20:17
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-09-23 20:17
Updated : 2026-09-24 21:00
NVD link : CVE-2026-84712
Mitre link : CVE-2026-84712
CVE.ORG link : CVE-2026-84712
JSON object : View
Products Affected
No product.
CWE
CWE-497
Exposure of Sensitive System Information to an Unauthorized Control Sphere