OpenTelemetry eBPF Instrumentation provides eBPF instrumentation based on the OpenTelemetry standard. Prior to version 0.9.0, the Postgres protocol parser assumes BIND message payloads contain a valid NUL-terminated portal name. A crafted empty or unterminated payload can make OBI slice beyond the end of the captured buffer and panic. This issue has been patched in version 0.9.0.
References
| Link | Resource |
|---|---|
| https://github.com/open-telemetry/opentelemetry-ebpf-instrumentation/releases/tag/v0.9.0 | Product Release Notes |
| https://github.com/open-telemetry/opentelemetry-ebpf-instrumentation/security/advisories/GHSA-pgvv-q3wf-mm9m | Exploit Vendor Advisory |
| https://github.com/open-telemetry/opentelemetry-ebpf-instrumentation/security/advisories/GHSA-pgvv-q3wf-mm9m | Exploit Vendor Advisory |
Configurations
History
No history.
Information
Published : 2026-06-02 16:16
Updated : 2026-07-22 19:10
NVD link : CVE-2026-45678
Mitre link : CVE-2026-45678
CVE.ORG link : CVE-2026-45678
JSON object : View
Products Affected
opentelemetry
- ebpf_instrumentation