Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.
The specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451.
References
| Link | Resource |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-26-157/ | Third Party Advisory |
Configurations
Configuration 1 (hide)
| AND |
|
History
No history.
Information
Published : 2026-03-16 14:19
Updated : 2026-06-17 10:43
NVD link : CVE-2026-3559
Mitre link : CVE-2026-3559
CVE.ORG link : CVE-2026-3559
JSON object : View
Products Affected
philips
- hue_bridge_v2
- hue_bridge_v2_firmware
CWE
CWE-323
Reusing a Nonce, Key Pair in Encryption
