An argument parsing error in the kill utility of uutils coreutils incorrectly interprets kill -1 as a request to send the default signal (SIGTERM) to PID -1. Sending a signal to PID -1 causes the kernel to terminate all processes visible to the caller, potentially leading to a system crash or massive process termination. This differs from GNU coreutils, which correctly recognizes -1 as a signal number in this context and would instead report a missing PID argument.
References
| Link | Resource |
|---|---|
| https://github.com/uutils/coreutils/pull/9700 | Issue Tracking Patch |
| https://github.com/uutils/coreutils/releases/tag/0.6.0 | Release Notes |
Configurations
History
No history.
Information
Published : 2026-04-22 17:16
Updated : 2026-06-17 10:40
NVD link : CVE-2026-35369
Mitre link : CVE-2026-35369
CVE.ORG link : CVE-2026-35369
JSON object : View
Products Affected
uutils
- coreutils
CWE
CWE-20
Improper Input Validation