CVE-2026-35073

Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.
Configurations

Configuration 1 (hide)

OR cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:data_domain_operating_system:*:*:*:*:*:*:*:*
cpe:2.3:o:dell:data_domain_operating_system:8.7.0.0:*:*:*:*:*:*:*

History

26 Oct 2026, 22:10

Type Values Removed Values Added
Summary
  • (es) Dell PowerProtect Data Domain, versiones 7.7.1.0 hasta 8.7.0.0, versiones de la edición LTS2025 8.3.1.0 hasta 8.3.1.20, versiones de la edición LTS2024 7.13.1.0 hasta 7.13.1.60 contienen una neutralización inadecuada de elementos especiales utilizados en una vulnerabilidad de inyección de comandos del sistema operativo. Un atacante con altos privilegios con acceso local podría potencialmente explotar esta vulnerabilidad, lo que llevaría a la ejecución arbitraria de comandos con privilegios de root.

14 Oct 2026, 15:17

Type Values Removed Values Added
Summary (en) Dell PowerProtect Data Domain Feature Release versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, and LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges. (en) Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization of special elements used in an OS command injection vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.

Information

Published : 2026-04-17 11:16

Updated : 2026-10-26 22:10


NVD link : CVE-2026-35073

Mitre link : CVE-2026-35073

CVE.ORG link : CVE-2026-35073


JSON object : View

Products Affected

dell

  • data_domain_operating_system
CWE
CWE-78

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')