An Improper Check for Unusual or Exceptional Conditions vulnerability in the chassis control daemon (chassisd) of Juniper Networks Junos OS on SRX1500, SRX4100, SRX4200 and SRX4600 allows a local attacker with low privileges to cause a complete Denial of Service (DoS).
When a specific 'show chassis' CLI command is executed, chassisd crashes and restarts which causes a momentary impact to all traffic until all modules are online again.
This issue affects Junos OS on SRX1500, SRX4100, SRX4200 and SRX4600:
* 23.2 versions before 23.2R2-S6,
* 23.4 versions before 23.4R2-S7
* 24.2 versions before 24.2R2-S2,
* 24.4 versions before 24.4R2,
* 25.2 versions before 25.2R1-S1, 25.2R2.
References
| Link | Resource |
|---|---|
| https://kb.juniper.net/JSA107873 | Mitigation Vendor Advisory |
Configurations
Configuration 1 (hide)
| AND |
|
History
No history.
Information
Published : 2026-04-09 22:16
Updated : 2026-06-17 10:38
NVD link : CVE-2026-33787
Mitre link : CVE-2026-33787
CVE.ORG link : CVE-2026-33787
JSON object : View
Products Affected
juniper
- srx1500
- srx4200
- srx4100
- srx4600
- junos
CWE
CWE-754
Improper Check for Unusual or Exceptional Conditions