NanoMQ MQTT Broker (NanoMQ) is an all-around Edge Messaging Platform. In NanoMQ version 0.24.6, after enabling auth.http_auth (HTTP authentication), when a client connects to the broker using MQTT CONNECT without providing username/password, and the configuration params uses the placeholders %u / %P (e.g., username="%u", password="%P"), the HTTP request construction phase enters auth_http.c:set_data(). This results in calling strlen() on a NULL pointer, causing a SIGSEGV crash. This crash can be triggered remotely, resulting in a denial of service. This issue has been patched in version 0.24.7.
References
| Link | Resource |
|---|---|
| https://github.com/nanomq/NanoNNG/commit/c20aa27e5290bb480a5315099952480d35f37a8b | Patch |
| https://github.com/nanomq/NanoNNG/pull/1394 | Issue Tracking Patch |
| https://github.com/nanomq/nanomq/releases/tag/0.24.7 | Product Release Notes |
| https://github.com/nanomq/nanomq/security/advisories/GHSA-77f4-wvq8-mp3p | Exploit Vendor Advisory |
Configurations
History
No history.
Information
Published : 2026-03-30 21:17
Updated : 2026-06-17 10:36
NVD link : CVE-2026-32696
Mitre link : CVE-2026-32696
CVE.ORG link : CVE-2026-32696
JSON object : View
Products Affected
emqx
- nanomq
CWE
CWE-476
NULL Pointer Dereference