A vulnerability exists in SenseLive X3050's web management interface that allows critical configuration parameters to be modified without sufficient authentication or server-side validation. By applying unsupported or disruptive values to recovery mechanisms and network settings, an attacker can induce a persistent lockout state. Because the device lacks a physical reset button, recovery requires specialized technical access via the console to perform a factory reset, resulting in a total denial-of-service for the gateway and its connected RS-485 downstream systems.
References
| Link | Resource |
|---|---|
| https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-111-12.json | Third Party Advisory |
| https://senselive.io/contact | Product |
| https://www.cisa.gov/news-events/ics-advisories/icsa-26-111-12 | US Government Resource |
Configurations
Configuration 1 (hide)
| AND |
|
History
No history.
Information
Published : 2026-04-24 00:16
Updated : 2026-06-17 10:27
NVD link : CVE-2026-27843
Mitre link : CVE-2026-27843
CVE.ORG link : CVE-2026-27843
JSON object : View
Products Affected
senselive
- x3500_firmware
- x3500
CWE
CWE-306
Missing Authentication for Critical Function