P-Net before 1.0.3 contains an integer underflow in pf_cpm_c_data_ind(). When handling a received cyclic data frame while the consumer is in the FRUN or RUN state, the offset of the APDU status was computed as the frame length minus 4 using 16-bit arithmetic, without checking that the frame is long enough. A crafted short frame makes the offset wrap around, so the function reads outside the receive buffer. This can cause a crash (denial of service) or disclose memory content.
CVSS
No CVSS.
References
Configurations
No configuration.
History
29 Oct 2026, 16:26
| Type | Values Removed | Values Added |
|---|---|---|
| New CVE |
Information
Published : 2026-10-29 16:17
Updated : 2026-10-29 16:26
NVD link : CVE-2026-111735
Mitre link : CVE-2026-111735
CVE.ORG link : CVE-2026-111735
JSON object : View
Products Affected
No product.