{"id": "CVE-2025-40947", "cveTags": [], "metrics": {"ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2025-40947", "role": "CISA Coordinator", "options": [{"exploitation": "none"}, {"automatable": "no"}, {"technicalImpact": "total"}], "version": "2.0.3", "timestamp": "2026-05-12T12:45:22.982292Z"}}], "cvssMetricV31": [{"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 7.5, "attackVector": "NETWORK", "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H", "integrityImpact": "HIGH", "userInteraction": "NONE", "attackComplexity": "HIGH", "availabilityImpact": "HIGH", "privilegesRequired": "LOW", "confidentialityImpact": "HIGH"}, "impactScore": 5.9, "exploitabilityScore": 1.6}], "cvssMetricV40": [{"type": "Secondary", "source": "productcert@siemens.com", "cvssData": {"Safety": "NOT_DEFINED", "version": "4.0", "Recovery": "NOT_DEFINED", "baseScore": 7.7, "Automatable": "NOT_DEFINED", "attackVector": "NETWORK", "baseSeverity": "HIGH", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "exploitMaturity": "NOT_DEFINED", "providerUrgency": "NOT_DEFINED", "userInteraction": "NONE", "attackComplexity": "HIGH", "attackRequirements": "NONE", "privilegesRequired": "LOW", "subIntegrityImpact": "NONE", "vulnIntegrityImpact": "HIGH", "integrityRequirement": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "vulnAvailabilityImpact": "HIGH", "availabilityRequirement": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "subConfidentialityImpact": "NONE", "vulnConfidentialityImpact": "HIGH", "confidentialityRequirement": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "vulnerabilityResponseEffort": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED"}}]}, "affected": [{"source": "productcert@siemens.com", "affectedData": [{"vendor": "Siemens", "product": "RUGGEDCOM ROX MX5000", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX MX5000RE", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1400", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1500", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1501", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1510", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1511", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1512", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1524", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX1536", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}, {"vendor": "Siemens", "product": "RUGGEDCOM ROX RX5000", "versions": [{"status": "affected", "version": "0", "lessThan": "V2.17.1", "versionType": "custom"}], "defaultStatus": "unknown"}]}], "published": "2026-05-12T10:16:43.053", "references": [{"url": "https://cert-portal.siemens.com/productcert/html/ssa-078743.html", "tags": ["Mitigation", "Vendor Advisory"], "source": "productcert@siemens.com"}], "vulnStatus": "Analyzed", "weaknesses": [{"type": "Secondary", "source": "productcert@siemens.com", "description": [{"lang": "en", "value": "CWE-78"}]}], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.1), RUGGEDCOM ROX MX5000RE (All versions < V2.17.1), RUGGEDCOM ROX RX1400 (All versions < V2.17.1), RUGGEDCOM ROX RX1500 (All versions < V2.17.1), RUGGEDCOM ROX RX1501 (All versions < V2.17.1), RUGGEDCOM ROX RX1510 (All versions < V2.17.1), RUGGEDCOM ROX RX1511 (All versions < V2.17.1), RUGGEDCOM ROX RX1512 (All versions < V2.17.1), RUGGEDCOM ROX RX1524 (All versions < V2.17.1), RUGGEDCOM ROX RX1536 (All versions < V2.17.1), RUGGEDCOM ROX RX5000 (All versions < V2.17.1). Affected devices do not properly sanitize user-supplied input during the feature key installation process.\r\n\r\nThis could allow an authenticated remote attacker to inject arbitrary commands, resulting in remote code execution with root privileges on the underlying operating system."}, {"lang": "es", "value": "Una vulnerabilidad ha sido identificada en RUGGEDCOM ROX MX5000 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX MX5000RE (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1400 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1500 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1501 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1510 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1511 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1512 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1524 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX1536 (Todas las versiones anteriores a V2.17.1), RUGGEDCOM ROX RX5000 (Todas las versiones anteriores a V2.17.1). Los dispositivos afectados no sanean correctamente la entrada proporcionada por el usuario durante el proceso de instalaci\u00f3n de la clave de caracter\u00edstica.\n\nEsto podr\u00eda permitir a un atacante remoto autenticado inyectar comandos arbitrarios, lo que resultar\u00eda en la ejecuci\u00f3n remota de c\u00f3digo con privilegios de root en el sistema operativo subyacente."}], "lastModified": "2026-10-23T22:10:00.160", "configurations": [{"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "8E959933-E882-45F7-AFE6-2A14DBD33D49", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "DAD1B18F-9C37-48CC-92E2-9C5E66B206CB"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_mx5000re_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "B55E56C2-C306-4CD8-AB16-83E174A95BBC", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_mx5000re:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "38734DFA-A5DF-4284-BD79-7C0ED6CD8A5C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1400_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "1490D50D-0645-4822-9900-96FF59CA77C7", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1400:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "12BD4008-DB6A-4749-A426-D2DE44819A9D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1500_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "95CD33F1-67A5-432E-8260-D9EF05527134", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1500:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "3E79B422-C844-411C-AA49-CFD73D3C6E2D"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1501_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "16EC7E53-11E3-4969-AE51-39E9E7727684", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1501:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "53AAEC5C-06EE-4C58-A981-EBF5860CEF16"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1510_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "0A6F6F6C-6265-4852-A682-99854378665B", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1510:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "0751225A-6E9C-4281-93A4-A048920FF7C6"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1511_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "D319D2D6-022E-4076-9C65-DF4D2FCF4C0D", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1511:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "8C1E56ED-1E61-4B7E-8EC0-BB2AAD57EF7B"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1512_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C2D73C42-CAC0-4023-88E2-321AC600DFA2", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1512:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "41ADD701-AD49-46B2-A12E-219CCED32298"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1524_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C21E1791-E434-4083-A19F-F304E44C4FD7", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1524:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "F8C70D90-E8FA-4343-9027-152A99D79C82"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx1536_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "C091E8A8-B401-40B4-BABF-C9C22FAF63EE", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx1536:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "C1775F3B-6F47-4134-8B4E-CF6337FF546C"}], "operator": "OR"}], "operator": "AND"}, {"nodes": [{"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:o:siemens:ruggedcom_rox_rx5000_firmware:*:*:*:*:*:*:*:*", "vulnerable": true, "matchCriteriaId": "F2E21053-160B-429A-A536-B6C2718DC3A0", "versionEndExcluding": "2.17.1"}], "operator": "OR"}, {"negate": false, "cpeMatch": [{"criteria": "cpe:2.3:h:siemens:ruggedcom_rox_rx5000:-:*:*:*:*:*:*:*", "vulnerable": false, "matchCriteriaId": "1E0E33F2-E89B-4008-BED2-CF2296801078"}], "operator": "OR"}], "operator": "AND"}], "sourceIdentifier": "productcert@siemens.com"}